3par Mib Downloads

  



  1. 3par Mib Downloads Software
  2. 3par Mib Downloads Pc
  3. 3par Mib Downloads Download
  4. 3par Mib Downloads App

In no event shall 3PAR have any liability arising out of or related to # customer's 'use of the script including lost data, lost profits, or any direct or indirect, incidental, special, or # consequential damages arising there from. The Service Pack for ProLiant (SPP) is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. This solution uses Smart Update Manager (SUM) as the deployment tool and is tested on all HPE ProLiant Gen9 and Gen10 servers as defined in the Service Pack for ProLiant Server Support Guide found at. Configuring the HPE 3PAR Storage System This portion of the document covers the necessary configuration for using an HPE 3PAR Storage System with an IBM SAN Volume Controller cluster. Support models of HPE 3PAR Storage Systems The HPE 3PAR Stor Serv (Models 7000, 10000) the HPE, Stor Serv (Models 8000 and 20000) are supported for use with the.

H,

i want check the 3PAR with cli, i found this script for nagios. It is possibile to use for prtg?

https://github.com/kishikawa/3par/blob/master/check_3par here is the script.

Thx


How about using the MIB file from the 3PAR admin tools CD.

Convert the MIB to a OIDLIB using Paesslers MIB converter. In PRTG, you will add an SNMP Library sensor and use the new OIDLIB file.

For more details on converting MIB files to OIDLIB files please see https://kb.paessler.com/en/topic/733-how-can-i-import-my-mib-files-into-prtg

No function, because 3PAR use a trap, and the beta sensor no function. The powershell script is the unique possibility to check the status.

Dear all

Is there in meantime any option to monitor a HP 3PAR 8200 System with SNMP ? Does somebody have some experience with this issues. Does it work with and MIB Files and converting to OIDLIB Files ?

@ PRTG Support : Are any HP 3PAR Sensors planned ?

3par Mib Downloads Software

Thanks for any help

Currently, there are no plans for 3PAR storage servers. The only way to go here would be to test the SSH SAN sensors or the trap receiver sensors. The former one might not work as its not tested for comptability with the 3PARs.

I am also interested in 3PAR sensors

Unfortunately, as stated in the 3par MIB:

Index to access entries in alert table. However, the table is empty most of the time because the entry is deleted after sending the trap
3par

This means that regular SNMP GET monitoring won't work, importing the MIB won't help. You may want to try the TRAPS approach:


The other alternative would be to create a custom script which interacts with the 3par in a different way (HTTP API, SSH, etc)


Best Regards,
Luciano Lingnau [Paessler Support]

We have recently developed a pack of 6 sensors for HPE 3Par.
Have a look at our website

Best regards, Yigal, KMC Technologies

3par Mib Downloads Pc

I am also interested in 3PAR sensors. We have some 3par Systems and we need to monitor them.

I am also interested in 3 par sensors.

Please log in or register to enter your reply.


Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.

3par Mib Downloads Download


Printable version

* RECOMMENDED * HPE Offline Bundle for ESXi 6.5

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type:Software - System Management
Version:3.6.0(5 Oct 2020)
Operating System(s): VMware vSphere 6.5
File name:esxi6.5uX-mgmt-bundle-3.6.0-9.zip (15 MB)
The HPE ESXi Offline Bundle for VMware ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries.

Agentless Management Service

Added the option to enable/disable AHS Logical Disk Usage logging

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

55bcdc680d52ad56d9428249eb6a702ba873ec94848ad096ea5712020ed3e54desxi6.5uX-mgmt-bundle-3.6.0-9.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Installing Offline Bundles on an vSphere 6.5 Host Using vSphere CLI 6.5 esxcli Utility

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes
the procedure using offline bundles.

Prerequisites
Before you can update or patch an vSphere 6.5 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.5 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the
vSphere CLI 6.5, see the VMware vSphere Command-Line Interface Installation and Reference Guide.

Procedure

  1. Power off any virtual machines that are running on the host and place the host into maintenance mode.
  2. Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
  3. Install the bundle on the ESXi host.
    • Install remotely from client, with offline bundle contents on a online depot:
      esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
    • Install remotely from client, with offline bundle on ESXi host:
      esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
    • Install from ESXi host, with offline bundle on ESXi host:
      esxcli software vib install -d <ESXi local path><bundle.zip>
  4. After the bundle is installed, reboot the ESXi host for the updates to take effect.
  5. (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
    esxcli -s <server> -u root -p mypassword software vib list
  6. (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
    esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>

Installing Offline Bundles on an vSphere 6.5 Host Using VMware vCenter Update Manager

The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.

End User License Agreements:
HPE Software License Agreement v1
Eclipse License
Libcurl End User License Agreement
Net-SNMP License
SNIA License
zlib End User License Agreement
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Notes:

The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License.
A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/

Supported Devices and Features:

VMware vSphere version support:

  • VMware vSphere 6.5 U2
  • VMware vSphere 6.5 U3

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default
Version:3.6.0 (5 Oct 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Agentless Management Service

Added the option to enable/disable AHS Logical Disk Usage logging


Version:3.5.0 (17 Jan 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
  • Fix memory leak issues causing ESXi host to become unresponsive or crash

Agentless Management Service

  • Fix buffer overrun when acquiring vib summary from ESXi host database
  • Fix cpqSePciSlotBoardName for empty slots with no CPU
  • Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
  • Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
  • Fix AMS hang when total IPv6 address string sizes exceed 256 bytes

Version:3.4.5 (16 Sep 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
  • Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes

Agentless Management Service

  • Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter

Version:3.4.0 (2 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider

Agentless Management Service

  • Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM

Agentless Management Service

  • Added support for cpqiscsi MIB
  • Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log

Version:3.3.6 (29 Nov 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
  • Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.

Version:3.3.0 (27 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed issue with Smart Array Provider reporting change of battery status frequently

Agentless Management Service

  • Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
  • Fixed memory leak partly caused by AMS running in the OS init resource group
  • Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display

WBEM Providers

  • Added support for Smart Array Controller model P408i-sb

Agentless Management Service

  • Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log

Version:3.2.0 (21 Mar 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
  • Fixed to report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5. For more information, see the customer advisory at http://h20566.www2.hpe.com/hpsc/doc/ public/display?docId=emr_na-a00016048en_us.
  • Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
  • Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
  • Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.

Agentless Management Service

  • Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system

Agentless Management Service

  • Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
  • Added support for HPE Smart Array P824i-p MR controller
  • Added support for reporting multiple IPV6 addresses configured for Ethernet ports
  • Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
  • Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers

Version:3.1.5 (9 Nov 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

HPE Insight Management WBEM Providers:

HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5

This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information.

HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5

This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.

HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated

When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.

Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.

HPE Agentless Management Service:

  • Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.
  • Fixed cpqIdeAtaDiskStatus which always shows SMART error and causing cpqIdeAtaDiskCondition as Degraded.

Added HPE Insight Management WBEM Provider support for new FCHBA.


Version:3.1.1 (28 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed Memory leak in HPE Insight Management WBEM Provider on VMware vSphere 6.5


Version:3.1.0 (12 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

AMS fixes:

  • Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
  • Fixed AMS crash when multiple NICs of the same driver are installed

WBEM Provider features:

  • Gen10 and newer servers are Agentless, meaning the providers are limited to only the part of the Smart Array provider required to support Smart Array in VMware vCenter. Full providers continue to be supported on Gen9 and earlier servers.
  • Added support for smartpqi driver and Gen10 Smart Array controllers.
  • Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility.
  • Added Firmware update audit logging support to Smart Component Installer provider

AMS features:

  • Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
  • Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor

The Agentless Management Service script to manually stop or restart AMS has changed from hp-ams.sh to ams.sh.


Version:2.6.2 (15 May 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • There is an updated hpe-ilo driver included in this bundle. For more information, see the VMware Knowledge Base Article at http://kb.vmware.com/kb/2148123and the HPE Customer Advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=c05378386.
  • HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if an nhpsa driver supported HPE Smart Array Controller is also configured in the same server on vSphere 6.5 - This issue is observed on vSphere 6.5 when the server is configured with a combination of a HPE Dynamic Smart Array B140i Controller that supports hpdsa driver and a HPE Smart Array Controller that supports an nhpsa driver. The HPE Insight Management WBEM Providers does not report the HPE Dynamic Smart Array B140i Controller instances and only reports the HPE Smart Array Controller instances that supports the nhpsa driver.


Version:2.6.0 (18 Nov 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Provider Features:

  • Added support for Native Interface in Ethernet Port Provider
  • Added support for Native interface in Smart Array Provider

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

Type:Software - System Management
Version:3.6.0(5 Oct 2020)
Operating System(s):
VMware vSphere 6.5

Description

The HPE ESXi Offline Bundle for VMware ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries.

Enhancements

Agentless Management Service

Added the option to enable/disable AHS Logical Disk Usage logging

Installation Instructions

To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value:

55bcdc680d52ad56d9428249eb6a702ba873ec94848ad096ea5712020ed3e54desxi6.5uX-mgmt-bundle-3.6.0-9.zip

Reboot Requirement:
Reboot is required after installation for updates to take effect and hardware stability to be maintained.

Installation:

Installing Offline Bundles on an vSphere 6.5 Host Using vSphere CLI 6.5 esxcli Utility

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic describes
the procedure using offline bundles.

Prerequisites
Before you can update or patch an vSphere 6.5 host from the command line, you must have access to a machine on which you can run the VMware vSphere Command-Line Interface 6.5 (vSphere CLI). You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about importing or installing the
vSphere CLI 6.5, see the VMware vSphere Command-Line Interface Installation and Reference Guide.

Procedure

  1. Power off any virtual machines that are running on the host and place the host into maintenance mode.
  2. Transfer the offline bundle onto the ESXi host local path, or extract it onto an online depot.
  3. Install the bundle on the ESXi host.
    • Install remotely from client, with offline bundle contents on a online depot:
      esxcli -s <server> -u root -p mypassword software vib install -d <depotURL/bundle-index.xml>
    • Install remotely from client, with offline bundle on ESXi host:
      esxcli -s <server> -u root -p mypassword software vib install -d <ESXi local path><bundle.zip>
    • Install from ESXi host, with offline bundle on ESXi host:
      esxcli software vib install -d <ESXi local path><bundle.zip>
  4. After the bundle is installed, reboot the ESXi host for the updates to take effect.
  5. (Optional) Verify that the vibs on the bundle are installed on your ESXi host.
    esxcli -s <server> -u root -p mypassword software vib list
  6. (Optional) Remove individual vibs. <vib name> can be identified by listing the vibs as shown in #5.
    esxcli -s <server> -u root -p mypassword software vib remove -n <vib name>

Installing Offline Bundles on an vSphere 6.5 Host Using VMware vCenter Update Manager

The offline bundle can also be installed from VMware vCenter Update Manager as a patch. For more information and detailed instructions, see the VMware vCenter Update Manager Administration Guide.

Release Notes

End User License Agreements:
HPE Software License Agreement v1
Eclipse License
Libcurl End User License Agreement
Net-SNMP License
SNIA License
zlib End User License Agreement
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Notes:

The HPE CIM Providers use modified SNIA HBAAPI open source code and is covered by the SNIA License.
A document of the changes made and the modified source code are available at http://vibsdepot.hpe.com/hpq/SNIA/HBAAPI/

Supported Devices and Features:

VMware vSphere version support:

  • VMware vSphere 6.5 U2
  • VMware vSphere 6.5 U3

Fixes

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Revision History

Version:3.6.0 (5 Oct 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Add support for distributed switch to resolve AMS issue of not reporting the Host IP address
  • Fix duplicate IP address reporting issue
  • Add fix to skip CPU and Memory Usage data collection when CPU and Memory Usage Logging is disabled
  • Disable Logical Disk Usage logging by default

Agentless Management Service

Added the option to enable/disable AHS Logical Disk Usage logging


Version:3.5.0 (17 Jan 2020)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fix incorrect CacheOperationalStatus data for Smart Array B140i Controller
  • Fix memory leak issues causing ESXi host to become unresponsive or crash

Agentless Management Service

  • Fix buffer overrun when acquiring vib summary from ESXi host database
  • Fix cpqSePciSlotBoardName for empty slots with no CPU
  • Fix cpqSePciSlotBoardName for FC Adapters with specific Device IDs
  • Disable multiple IPv6 support in Gen9 to fix Host discovery issues due to missing support in iLO
  • Fix AMS hang when total IPv6 address string sizes exceed 256 bytes

Version:3.4.5 (16 Sep 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed issue with AMS filling up tmp and causing VUM updates to Fail (https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00073323en_us)
  • Fixed issue with read spikes seen in Gen9 hosts with HPE 3PAR only every 5 minutes

Agentless Management Service

  • Added support for HPE Ethernet 10Gb 2-port 524SFP+ Adapter and HPE Ethernet 10Gb 2-port 548SFP+ Adapter

Version:3.4.0 (2 Apr 2019)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed false Solid State Disk Wear alert reported by the SmartArray WBEM provider

Agentless Management Service

  • Fixed reporting of HPE QLogic NX2 driver components in the cpqHoSwVer MIB to resolve blank Installed driver versions displayed in SUM

Agentless Management Service

  • Added support for cpqiscsi MIB
  • Implement configurable CPU and Memory Usage periodic logging to the iLO AHS (Active Health System) Log

Version:3.3.6 (29 Nov 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Agentless Management Service

  • Fixed reporting of HPE Software in the cpqHoSwVer MIB to resolve blank Active versions for installed drivers displayed in SUM.
  • Fixed AMS crash when processing a Link Down/Up Trap for a NIC port that has multiple IPV6 addresses.

Version:3.3.0 (27 Jun 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed issue with Smart Array Provider reporting change of battery status frequently

Agentless Management Service

  • Fixed to remove heartbeat trap (cpqHo2GenericTrap) delivery at OS boot when periodic test trap feature is disabled
  • Fixed memory leak partly caused by AMS running in the OS init resource group
  • Fixed reporting of the embedded SATA controller to resolve missing drives in the iLO Storage Tab display

WBEM Providers

  • Added support for Smart Array Controller model P408i-sb

Agentless Management Service

  • Added reporting of OS Logical Disk Volume Configuration and Utilization to iLO's Active Health System Log

Version:3.2.0 (21 Mar 2018)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

WBEM Providers

  • Fixed to report HPE Smart array P816i-a SR Gen10 controller Information on vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019315en_us.
  • Fixed to report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5. For more information, see the customer advisory at http://h20566.www2.hpe.com/hpsc/doc/ public/display?docId=emr_na-a00016048en_us.
  • Fixed Memory leak issue in HPE Insight Management WBEM Provider on VMware vSphere 6.0 and 6.5. For more information, see the customer advisory at http:// h20566.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.
  • Fixed to report HealthState property for HPVC_SAStorageVolume and HPVC_SAStorageExtent to match SSACLI status.
  • Fixed number of HPVC_SAStorageVolume instances to match with SSACLI.

Agentless Management Service

  • Fix continuous PCIe Disk Temperature Failed (cpqSePCIeDiskTemperatureFailed) and PCIe Disk Wear Status Change (cpqSePCIeDiskWearStatusChange) traps when there are 3 or more NVMe drives in the system

Agentless Management Service

  • Added reporting of proper part number for HPE Dual 8GB MicroSD EM USB Device
  • Added support for HPE Smart Array P824i-p MR controller
  • Added support for reporting multiple IPV6 addresses configured for Ethernet ports
  • Added support for Periodic heartbeat trap (cpqHo2GenericTrap)
  • Added support for Host OS Graceful shutdown due to Critical Thermal/Fan Failure events in HPE Gen10 Servers

Version:3.1.5 (9 Nov 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

HPE Insight Management WBEM Providers:

HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if nhpsa driver supported Smart Array Controller is also configured in that server on vSphere 6.5

This issue is observed on vSphere 6.5 when the server is configured with an HPE Dynamic Smart Array B140i Controller supported by the hpdsa driver and smart array controller supported by the nhpsa driver. In this configuration, the HPE Insight Management WBEM Provider do not report the HPE Dynamic Smart Array B140i Controller instances information it only reports the Smart Array Controller instances information.

HPE Insight Management WBEM Providers does not support HPE Smart Array P816i-a SR Gen10 controller on vSphere 6.0 and 6.5

This issue is observed on both vSphere 6.0 and 6.5 OS, when the server is configured with HPE Smart Array P816i-a SR Gen10 controller. In this configuration, the HPE Insight Management WBEM Providers do not report any information of the HPE Smart Array P816i-a SR Gen10 controller.

HPE Insight Management WBEM Providers is not reporting the actual OperationalStatus of FC port and WBEM indications are also not generated

When FC Adapter “HP FlexFabric 10Gb 2-port 536FLB” is installed on a server and the FC cable is connected or disconnected from ports, HPE Insight Management WBEM Providers report wrong value for the OperationalStatus property in FC Provider classes and the WBEM indications are not generated. OperationalStatus reports the changed status only after WBEM Provider restarts.

Fixed memory leak. For more information, see the customer advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-a00019892en_us.

HPE Agentless Management Service:

  • Fixed status for unconnected Fiber Channel ports that cause Fiber Channel Controller status to show as Degraded.
  • Fixed cpqIdeAtaDiskStatus which always shows SMART error and causing cpqIdeAtaDiskCondition as Degraded.

Added HPE Insight Management WBEM Provider support for new FCHBA.


Version:3.1.1 (28 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Fixed Memory leak in HPE Insight Management WBEM Provider on VMware vSphere 6.5


Version:3.1.0 (12 Jul 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

AMS fixes:

  • Fixed /tmp folder exhaustion with ahs.debug file when running over 128 CPU threads on the Host Server
  • Fixed AMS crash when multiple NICs of the same driver are installed

WBEM Provider features:

  • Gen10 and newer servers are Agentless, meaning the providers are limited to only the part of the Smart Array provider required to support Smart Array in VMware vCenter. Full providers continue to be supported on Gen9 and earlier servers.
  • Added support for smartpqi driver and Gen10 Smart Array controllers.
  • Added support to send Test Indication periodically to all the subscribers based on the time-interval value(days) configured from testevent utility.
  • Added Firmware update audit logging support to Smart Component Installer provider

AMS features:

  • Added new SMA (System Management Assistant) feature for Gen10 which allows SNMP traps generated by iLO Agentless Management and AMS to be delivered through the Host OS Management Port
  • Added support for new MIB OIDs cpqSasPhyDrvSsBoxModel, cpqSasPhyDrvSsBoxSerialNumber, cpqSasPhyDrvSsBoxFwRev, and cpqSasPhyDrvSsBoxVendor

The Agentless Management Service script to manually stop or restart AMS has changed from hp-ams.sh to ams.sh.


Version:2.6.2 (15 May 2017)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

  • There is an updated hpe-ilo driver included in this bundle. For more information, see the VMware Knowledge Base Article at http://kb.vmware.com/kb/2148123and the HPE Customer Advisory at http://h20565.www2.hpe.com/hpsc/doc/public/display?docId=c05378386.
  • HPE Insight Management WBEM Providers does not report HPE Dynamic Smart Array B140i Controller Information if an nhpsa driver supported HPE Smart Array Controller is also configured in the same server on vSphere 6.5 - This issue is observed on vSphere 6.5 when the server is configured with a combination of a HPE Dynamic Smart Array B140i Controller that supports hpdsa driver and a HPE Smart Array Controller that supports an nhpsa driver. The HPE Insight Management WBEM Providers does not report the HPE Dynamic Smart Array B140i Controller instances and only reports the HPE Smart Array Controller instances that supports the nhpsa driver.


Version:2.6.0 (18 Nov 2016)

Upgrade Requirement:
Recommended - HPE recommends users update to this version at their earliest convenience.

Provider Features:

  • Added support for Native Interface in Ethernet Port Provider
  • Added support for Native interface in Smart Array Provider

AMS features:

  • Added support for new SNMP traps for HPE NVMe PCIe Solid State Drives

3par Mib Downloads App

Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.